Flexible stop could provide shock protection for MEMS accelerometer. By modeling and simulation, the paper studied the response of a closed-loop MEMS accelerometer with stop under shock of different amplitudes and pulse width. Contact force plays an important role and the shock response shows strong nonlinearity due to the contact mechanism. A kind of double-cascaded stop is proposed to mitigate high-frequency shock failure. MEMS accelerometers with flexible stop and with double-cascaded stop are both designed and fabricated based on SOG (silicon on glass) technology. Compared with shock tests of accelerometers with hard cylinder stop, flexible stop could withstand more than 1e4g shock with about 100μs pulse width. Double-cascaded stop is more robust to high frequency shock.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.