Abstract

To assess agreement between endoanal sonography, endoanal magnetic resonance (MR) imaging, and surgery in depiction and classification of fistula in ano. Twenty-eight consecutive patients with nonspecific, cryptoglandular fistula in ano were studied. The fistulas were classified with endoanal sonography, endoanal MR imaging, and surgery. Agreement between the modalities was also evaluated. Classification of fistulas was possible in 17 of 28 patients (61%) with sonography, in 25 of 28 (89%) with MR imaging, and in 26 of 28 (93%) with surgery. Concordance between endoanal sonography and MR imaging occurred in 46% of the cases (kappa = 0.27, poor agreement); between sonography and surgery in 36% (kappa = 0.09, no agreement); and between MR imaging and surgery in 64% (kappa = 0.43, moderate agreement). Endoanal MR imaging more accurately allows depiction and classification of fistula in ano than endoanal sonography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.