At the present work, we have studied high-intensity ultrasound fields of standing cylindrical waves, generated by cylindrical piezoelectric transducer with radial polarization in its internal volume filled by liquid. The paper is focused on the study of length-extensional and thickness vibrational modes of cylindrical piezoelectric transducer. We have performed the finite-element simulations of standing cylindrical waves formation inside the cylindrical transducer filled with a liquid by those oscillation modes of piezoelectric cylinder using ANSYS software package and compared effectiveness of different regimes of standing waves generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.