Abstract

Heat runs of large asynchronous machines (AM) are hardly ever conducted under load but with synthetic approaches, such as the two-frequency method. In its classical variant, the AM's stator is fed by two series-connected synchronous machines (SM) with different frequencies, for instance 50 and 40 Hz. While the 50 Hz voltage determines the AM's flux, the 40 Hz source causes an AM stator current close to its rated value. Together, voltage and current yield approximately full load losses in the AM without mechanical loading. For designing the amortisseurs of the synchronous generators, damper losses were calculated using the Finite Element method. Additionally, calculated full load AM losses were compared against their respective values for the two- frequency method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.