Abstract
A solution to the finite cylinder-source model for the ground heat exchangers at a different buried depths that takes into account the heat capacity inside them and allows arbitrary heat rate changes is presented. Analytical expressions for the average ground temperature are derived by integrating the exact solutions over the cylinder-source depth for vertical and time-dependent changes of heat rate. The influence of buried depth variations on thermal response to a constant and uniform mean heat rate of the cylinder-source is examined by the integral mean temperature method in a self-consistent approach. In addition, approximate expressions for steady-state average temperature are derived for periodic heat rate in the long-time limit.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.