Abstract

Computational experiments were performed to study the influence of microchannel width and aspect ratio on performance of a four-compartment, microchannel heat sink with dedicated coolant inlet and outlet for each compartment. Wide range of coolant velocity (0.25–2m/s) & aspect ratio (2–10) and a reasonable range of microchannel width (100–200μm) have been simulated. The appropriate microchannel width and aspect ratio were found to be 200μm and 6, as evidenced from lowest total thermal resistance and lowest non-uniformity of substrate temperature at comparable power consumption among different microchannel widths and aspect ratios simulated. A new parameter ‘ω’ has been proposed for representation of substrate temperature gradient considering maximum, average and minimum substrate temperatures. Correlations have been developed for prediction of dimensionless pumping power, Nusselt number and dimensionless total thermal resistance. Hence, the four compartment heat sink with 200μm wide channels of aspect ratio 6 can be used for energy-efficient thermal management.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.