Abstract

AbstractA correction factor to the theoretical fin efficiency of serrated fins, reported in Part 1 and Part 2 of this report, was derived for an inline arrangement experimentally. The experiment was performed using an open‐type wind tunnel with six kinds of test finned‐tubes made of copper, carbon steel and stainless steel, which were arranged in one to five rows. Heat transfer measurement was done by the local thermal simulation method. The derived correction factor for the 1st row was the same as for staggered arrangement reported in Part 3, for the 2nd and deeper rows, however, a further correction was needed, which may be caused by the difference in the nonuniformity in heat transfer coefficient over the fin surface. © 2004 Wiley Periodicals, Inc. Heat Trans Asian Res, 33(4): 258–269, 2004; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/htj.20008

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.