From September 2012 to March 2013, a total of 63 adult-to-adult living donor liver transplantations were performed at our institution. All the patients were monitored for their coagulation functions using rotation thromboelastometry (ROTEM, Tem Innovations GmbH) during the procedure at the following points: preoperative baseline, 5 minutes, 30 minutes, and 120 minutes, respectively, after reperfusion of the liver graft. A total of 84.13% of cases (n = 53) revealed fibrinolysis after reperfusion of the graft and the condition was reversed after 30 minutes without any need for additional treatment. No significant coagulopathy was observed during this period in all of the cases. The result of the ROTEM finding must correlate with the clinical situation before instituting any management to avoid the risk of thrombosis of the hepatic artery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.