Abstract

Microneurosurgical technique has a steep learning curve. An alternative to microepineurial suture repair of peripheral nerves that circumvents this learning curve would be ideal. We investigated the effect of surgeon experience on suture versus fibrin glue coaptations in a mouse sciatic nerve graft model. Sixty-four mice received sciatic nerve grafts with either suture or fibrin glue repair by either a naïve surgeon (medical student) or a surgeon with extensive microsurgical experience. Grafts underwent quantitative histomorphometry at 3 weeks postoperatively. Suture repairs performed by the naïve surgeon demonstrated significantly poorer distal regeneration than all other repairs. Histomorphometric parameters of suture and glue repairs performed by the experienced surgeon were not significantly different from the glue coaptation by the naïve surgeon. Fibrin glue may be considered as an alternative to microepineurial suture repair, particularly in the setting of relative surgeon inexperience with microsurgical technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.