Abstract

In this work an all optical hot-wire flowmeter based on a silver coated fibre incorporating a long period grating and a Bragg grating is demonstrated. Optical energy at 1480 nm propagating down the fibre is coupled by the long period grating into the fibre cladding and absorbed by the metallic coating deposited on the fibre surface over the Bragg grating position. This absorption acts like a hot-wire raising locally the fibre temperature, which is effectively detected by the FBG resonance shift. The temperature raise depends on the flow speed of the surrounding air that has the effect to cool the fibre. In this way, the FBG Bragg wavelength shift can be related with the flow speed. Results obtained demonstrate the working principle and a flow speed resolution of 0.08 m/s is demonstrated.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.