BackgroundWe undertook a comparative biomechanical study of type B1 fractures around femoral prostheses following cemented hip arthroplasty using the Ortho-Bridge System (OBS) and a locking compression plate/locking attachment plate structure (LCP + LAP). We aimed to investigate the biomechanical characteristics and advantages of the OBS compared with LCP + LAP when treating this fracture type.MethodsAn OBS fixation model was designed based on OBS and LCP + LAP fixation characteristics. The LCP + LAP combination (Group A) and three different OBS combinations (Groups B, C, and D) were used to fix a B1 fracture model with a femoral periprosthetic fracture. Axial compression and torsion experiments were then performed using simple and comminuted fracture models. The axial compression failure experiment was carried out, and the model stiffness during axial compression, torsion angle in torsion test, and vertical load in the final failure test were collected.ResultsWhen simulating simple oblique fractures, no significant difference was found among the four groups in terms of stiffness in the axial compression experiment (P = 0.257). The torsion angle of the LCP + LAP system was significantly higher compared with the OBS system (P < 0.05). When simulating a comminuted fracture, the experimental data for axial compression showed that the rigidity measurements of the three combinations of the OBS system were higher compared with the LCP + LAP system (P = 0.000) and that the torsion angles of three combinations of the OBS system were smaller compared with the LCP + LAP system (P < 0.05). In the axial compression failure test, the fixed failure mode of the LCP + LAP system was the destruction of the contact cortex at the fracture site, whereas the failure modes in the three OBS combinations involved fracture around the screws above the osteotomy and destruction of the contact cortex at the fracture site.ConclusionsThe findings revealed that the OBS produced superior biomechanical outcomes compared with LCP + LAP, especially for the bridging two-rod dual cortex. According to the performance observed after model axial compression destruction, the OBS was fixed and provided greater stress dispersion, which might make it more suitable for facilitating early functional movement and avoiding the failure of internal fixation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.