Abstract

Feedforward and PID-SISO feedback control are compared on a pilot plant scale distillation column which is operated in the LV-configuration. For the rejection of disturbances in the feed concentration, a simple empirical feedforward control algorithm is presented. Final steady-state values of the manipulated variables are computed from quadratic equations in xF, which are easily fitted to simulation or plant data. Experimental results for PID- and feedforward control are compared. The need for dynamic filtering of manipulated variables is demonstrated. While direct setting of the manipulated variables may disturbe the system unnecessarily, second order filtering achieves very fast disturbance rejection. The impact of errors in the disturbance measurement on the control performance is investigated. The feedforward algorithm is intentionally kept simple, to allow easy implementation on a standard decentralized control system

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.