Abstract

The input-series and output-parallel (ISOP) DC transformer, which has no output filter, runs under near 100% duty ratio, and is easily achieve zero voltage switching (ZVS) conditions and higher efficiency, is more and more attractive in the high input voltage and high power applications. In order to achieving input voltages sharing in ISOP DC transformer based on two non-resonant DC transformer modules, the feed-forward control method is proposed in this paper. And the principle of the proposed control is analyzed in detail. Finally, experimental results are given to verify the proposed control method to have a good ability of sharing the input voltages.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.