Abstract

ABSTRACT In this study, an unconventional approach to electronic cooling is described, and its feasibility is investigated. This approach makes use of the transverse oscillations of a short plate placed in close proximity to the electronic component to provide for focused and localized cooling. This method can be applied for intermediate cooling rates, above those of natural convection, in order to extend the no-fan regime. To estimate the cooling potential, a numerical simulation of the temperature field in a channel formed by an oscillating surface and a fixed constant heat flux surface is performed. The results show that transverse oscillations have the potential for significant cooling enhancement compared to pure natural convection. The cooling effect is found to increase with the oscillation amplitude and channel length to mean width ratio and, to a lesser extent, with the oscillation frequency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.