Abstract

In large-scale cohort studies, sedentary behavior has been routinely measured using self-reports or devices that apply a count-based threshold. We employed a gold standard postural allocation technique using thigh inclination and acceleration to capture free-living sedentary behavior. Participants aged 46.8 (standard deviation (SD), 0.7) years (n = 5,346) from the 1970 British Cohort Study (United Kingdom) were fitted with a waterproofed thigh-mounted accelerometer device (activPAL3 micro; PAL Technologies Ltd., Glasgow, United Kingdom) worn continuously over 7 days; data were collected in 2016–2018. Usable data were retrieved from 83.0% of the devices fitted, with 79.6% of the sample recording at least 6 full days of wear (at least 10 waking hours). Total daily sitting time (average times were 9.5 (SD, 2.0) hours/day for men and 9.0 (SD, 2.0) hours/day for women) accounted for 59.4% and 57.3% of waking hours in men and women, respectively; 73.8% of sample participants recorded ≥8 hours/day of sitting. Sitting in prolonged bouts of 60 continuous minutes or more accounted for 25.3% and 24.4% of total daily sitting in men and women, respectively. In mutually adjusted models, male sex, underweight, obesity, education, poor self-rated health, television-viewing time, and having a sedentary occupation were associated with higher device-measured sitting times. Thigh-worn accelerometry was feasibly deployed and should be considered for larger-scale national surveys.

Highlights

  • In large-scale cohort studies, sedentary behavior has been routinely measured using self-reports or devices that apply a count-based threshold

  • Such studies are important to explore the feasibility of deploying a potentially more invasive device attached to the skin so that this methodology could be considered for larger-scale national surveys in the future

  • We report on rates of consent and adherence to the device-wear protocol

Read more

Summary

Introduction

In large-scale cohort studies, sedentary behavior has been routinely measured using self-reports or devices that apply a count-based threshold. Participants aged 46.8 (standard deviation (SD), 0.7) years (n = 5,346) from the 1970 British Cohort Study (United Kingdom) were fitted with a waterproofed thigh-mounted accelerometer device (activPAL3 micro; PAL Technologies Ltd., Glasgow, United Kingdom) worn continuously over 7 days; data were collected in 2016–2018. The thigh-mounted accelerometer has been used in relatively small convenience samples far [12, 18], the present study is the first (to our knowledge) to have used this approach in a large general population sample Such studies are important to explore the feasibility of deploying a potentially more invasive device attached to the skin (compared with devices worn around the wrist or attached to waist belts) so that this methodology could be considered for larger-scale national surveys in the future

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.