Abstract

In this study, a wastewater heat pump system was proposed and its thermal performance was analyzed. The proposed system includes two evaporators: an air-source evaporator and a water-source evaporator. The air-source evaporator absorbs heat from the moist hot air which exhaust from the drying oven. The water-source evaporator absorbs heat from the waste water, while the waste water recovers heat from the mechanical energy, which was produced by cutting and polishing in stone production. The thermodynamic model was developed to evaluate the performance of the proposed system. The energetic analysis was carried out to investigate the influences of the temperature of fresh air. The results show significantly higher energy efficiency, compact-sized and energy-saving compared with the system which uses air as the heat source. Among the seven of alternative refrigerants (R152a, R123, R1234yf, R1234ze, R600a, R22 and R600) investigated, R123 was suggested to be used in this heat pump for its high heating efficiency, inflammable, very low ODP(Ozone Depletion Potential) and GWP(Global warming potential).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.