Abstract
Disposal of fat, oil and grease (FOG) in sewer systems cause blockages, fatal errors of pumping stations, increased maintenance, odours, hydrogen sulphide (H2S) emissions and corrosion. Hence, solutions to prevent FOG disposals are desirable. Challenges are prevention of FOG contamination of sewer systems and removal of FOG disposals. A survey and lab as well as full scale tests were performed. In the first place fat traps and grease inceptors should be installed to prevent FOG contamination what is documented as being very effective. A case study shows that the operation of fat traps may indeed produce further problems, especially H2S emissions, what demands an additional treatment. Removal of FOG disposals can be handled by applying enzymes to the affected sewer network. It was found that enzymes are preferable towards surfactants to remove FOG disposals. It appears to be a solution to have one dosing site that is equipped with separately controlled dosing pumps for conditioners for H2S removal as well as FOG removal.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.