Abstract
We present a new position-sensitive fast neutron detector for 14 MeV fast neutron radiography, comprising a high-density polyethylene converter, a micro-channel plate (MCP), a P43 phosphor screen, a reflection mirror, and a CCD camera. Experimental tests are conducted using a DT neutron generator at CIAE, with different samples and a knife-edge measurement used to determine overall image resolution. Results show that the detector is feasible for fast neutron radiography, producing a fast neutron image with a neutron flux of ∼ 3.22 × 104 n · s-1 · cm-2 and 120 s exposure time. Our study demonstrates the potential of this detector for use in fast neutron radiography applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.