Abstract
A fast clean-up procedure for the low level analysis of polychlorinated dibenzo- p-dioxins, polychlorinated dibenzofurans and coplanar polychlorinated biphenyls in highly fatty biological matrices using high capacity disposable multi-layer silica columns is presented. Results were compared with gel permeation chromatography for removal of lipids. Analytical criteria such as recovery rates, repeatability, reproducibility and robustness are evaluated through a broad range of biological matrices and reference materials analysis. The final proposed procedure for the complete analysis, including pressurized liquid extraction, Power-Prep system clean-up and GC–high-resolution MS analysis requires only 48 h, and allows the simultaneous preparation of up to 10 samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.