Abstract

This paper treats the study of the equivalent magnetic flux leakage transformer core type; it uses three-phase high voltage power supplies for a magnetron in each phase. This special transformer feeds a voltage doubler, a current stabilizer cell in series per phase. It ensures the anodic current stabilization in each magnetron by saturation of its magnetic circuit. It has additional leakage flux, which protects the magnetron against any eventual voltage variation; it is considered the basic element of this power supply.The simulation results with MATLAB-Simulink environment of the electrical operation of this power supply device were consistent with the experimental laboratory tests in the case of single-phase high voltage for one magnetron. This results obtained shows the feasibility of the proposed simulation model

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.