Abstract
This study investigates the failure of an industrial cooling water pump which experienced a drive shaft failure. As per the fail-safe design, during adverse loading of the shaft, key should fail by shear. The key, if fails, can be easily replaced to resume the operation of the pump. However, this investigation reveals that both the key and the shaft failed due to materials processing issues. A detailed failure analysis was carried out including design calculations, visual inspection, dye penetrant inspection, magnetic particle inspection, hardness test, microstructural analysis, and fractography. The study found that the hardness of the shaft varied radially from the core to the surface. The subsurface of the shaft near the keyway, happened to be significantly softer than the key. During operation, the keyway widened by plastic deformation and caused rattling of the key. Due to rattling and vibration, the key developed numerous fatigue cracks and eventually failed by crack linkages. The shaft eventually failed by torsional shear near the midpoint of the keyway. The analysis adjudged hardness variation in the shaft due to materials processing issues as the root cause of the failure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.