Abstract
The interesting properties of Al 6061 aluminum foams have boosted the research on the correlation between foam composition and morphology and its mechanical response under dynamic conditions. In this study, ingots of an Al 6061-T4 foam were sectioned and analyzed in order to determine their microstructural and morphological characteristics, and then quasi-static and dynamic tests (10−3 to 3 × 102 s−1) were carried out to determine the material mechanical behavior. Dynamic tests, carried out by using the split Hopkinson bar, highlighted that the studied foam is characterized by a very good energy absorption capability, due to its ductile behavior. Nevertheless, the conducted research showed that cell morphology and distribution affect its mechanical behavior in dynamic conditions in which localized cell collapse may result in a decreased energy absorption and efficiency of the foam.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.