Abstract

The paper presents a failure analysis of tower axle in the water tank wire drawing machine. Material of the tower axle is 40Cr steel. In order to analyze the failure reasons of tower axle in the water tank wire drawing machine, we take experimental means such as morphological analysis, mechanical property testing, micro-metallography and scanning electron microscopy (SEM) of fracture observation, etc. The results show that the fracture of tower axle belongs to brittle fracture. The content of inclusions is more, and the composition is complex in the material. The heat treatment technology is improper. Improper quenched and tempered processing technologies cause more reticular and blocky ferrite in the steel. These are the main reasons for fracture of the tower axle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.