Abstract

The wall thickness of the sewage pipeline on a shale gas platform is seriously reduced. In order to explore the specific reasons for the pipeline failure, this paper carried out analysis by means of macroscopic inspection, mechanical property test, chemical composition analysis of base metal and corrosion product analysis. The analysis results show that the site of this pipeline corroded most seriously is at 5 o ′clock and 12 o ′clock near the outlet, and the corrosion of liquid accumulation containing CO2 is the main reason for the serious failure of the inner wall of this pipeline. This paper explores the specific reasons for the failure of the sewage pipeline on a shale gas platform, and provides a reference for the corrosion prevention of the sewage pipeline.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.