Abstract

Dual charge pump data show a reduction of circuit output voltage with dose. Through testing of individual process monitors, the response is identified as parasitic interdevice leakage caused by trapped oxide charge buildup in the isolation oxide. A library of compact models is generated for the field oxide parasitic based on test structure data along with 2-D structure simulation results. The charge pump schematic is then back annotated with transistors representative of the parasitic at different dose levels. Inclusion of the parasitic devices in schematic allows for simulation of the entire circuit at a specific dose. The reduction of circuit output with dose is then re-created in simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.