Abstract

With the improvement of family life quality and the implementation of energy-saving green household appliances, the volume of refrigerator increases rapidly and the energy efficiency ratio continues to decrease. However, the compressor size is required to be smaller, and the startup and shutdown are more frequent, which aggravates the wear of crankshaft connecting rod. Here, the failure compressor (300 ppm) provided by the manufacturer was disassembled and analyzed. The results showed that there were abrasive wear and adhesive wear on the surface of crankshaft and connecting rod. The source of solid particles in compressor was further analyzed, and the process control measures were proposed. In addition, combined with its failure mechanism and production process, the crankshaft surface composite treatment process was designed and bench test was carried out, which shows excellent anti-wear and self-lubricating performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.