Abstract

We provide a workflow to extract unidentified signals from chromatography-high resolution mass spectrometry (LC-HRMS) data of wastewater samples as a pre-step of a non-targeted analysis of dissolved organic matter (DOM). We provide detailed methodology on data processing and cleanup using MS processing software MZmine 2 and an own set of functions in R developed for wastewater analysis. The processing involves signal extraction, linear mass correction, reduction of noise, grouping of isotopologues, molecular formula assignment and merging of replicates. The article contains software settings and reasoning behind the choice of data extraction options. The supplementary information contains a script for the correction of signal masses using internal standards and templates of internal standard lists. We included a reproducible example as an R notebook with data cleansing workflow and data exported from MZmine. The data were used according to the described methodology in the article “A non-targeted high-resolution mass spectrometry data analysis of dissolved organic matter in wastewater treatment” by Verkh et al., 2018.•Includes a linear mass correction algorithm for LC-HRMS signals.•Describes a pipeline of non-targeted processing of LC-HRMS data of wastewater using free software.•Provides tests and reasons for parameter choice in non-targeted LC-HRMS wastewater data extraction.

Highlights

  • We provide a workflow to extract unidentified signals from chromatography-high resolution mass spectrometry (LC-HRMS) data of wastewater samples as a pre-step of a non-targeted analysis of dissolved organic matter (DOM)

  • The data were used according to the described methodology in the article “A non-targeted high-resolution mass spectrometry data analysis of dissolved organic matter in wastewater treatment” by Verkh et al, 2018

  • The methodology was developed and tested with LC-HRMS data recorded on an Orbitrap Velos mass spectrometer

Read more

Summary

Method Article

A Catalan Institute for Water Research (ICRA), Carrer Emili Grahit 101, 17003 Girona, Spain b Ruper Boškovic Institute, Bijenic9ka cesta 54, 10000, Zagreb, Croatia c Catalan Institution for Research and Advanced Studies (ICREA), Passeig Lluís Companys 23, 08010, Barcelona, Spain

Method details
Findings
Method validation
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.