Abstract
BackgroundCardiac involvement determines outcome in patients with systemic amyloidosis. There is major unmet need for quantification of cardiac amyloid burden, which is currently only met in part through semi-quantitative bone scintigraphy or Cardiovascular Magnetic Resonance (CMR), which measures ECVCMR. Other accessible tests are needed. ObjectivesTo develop cardiac computed tomography to diagnose and quantify cardiac amyloidosis by measuring the myocardial Extracellular Volume, ECVCT. MethodsTwenty-six patients (21 male, 64 ± 14 years) with a biopsy-proven systemic amyloidosis (ATTR n = 18; AL n = 8) were compared with twenty-seven patients (19 male, 68 ± 8 years) with severe aortic stenosis (AS). All patients had undergone echocardiography, bone scintigraphy, NT-pro-BNP measurement and EQ-CMR. Dynamic Equilibrium CT (DynEQ-CT) was performed using a prospectively gated cardiac scan prior to and after (5 and 15 minutes) a standard Iodixanol (1 ml/kg) bolus to measure ECVCT. ECVCT was compared to the reference ECVCMR and conventional amyloid measures: bone scintigraphy and clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area). ResultsECVCT and ECVCMR results were well correlated (r2 = 0.85 vs r2 = 0.74 for 5 and 15 minutes post bolus respectively). ECVCT was higher in amyloidosis than AS (0.54 ± 0.11 vs 0.28 ± 0.04, p<0.001) with no overlap. ECVCT tracked clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area), and bone scintigraphy amyloid burden (p<0.001). ConclusionDynamic Equilibrium CT, a 5 minute contrast-enhanced gated cardiac CT, has potential for non-invasive diagnosis and quantification of cardiac amyloidosis.
Highlights
Certain types of bone scintigraphy[10,11] and conventional cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE)[12] can detect cardiac amyloid, neither is truly quantitative and both have limitations e for example, bone tracers are insensitive in AL amyloidosis and SAP scintigraphy does not image cardiac amyloid
ECVCT at 5 minutes was strongly correlated with ECVCMR (r2 1⁄4 0.85, p
Bland-Altman comparisons of ECVCT and ECVCMR demonstrated no bias at 5 minutes post contrast, with slight bias at 15 minutes (4%, no slope)
Summary
There is major unmet need for quantification of cardiac amyloid burden, which is currently only met in part through semi-quantitative bone scintigraphy or Cardiovascular Magnetic Resonance (CMR), which measures ECVCMR. All patients had undergone echocardiography, bone scintigraphy, NT-pro-BNP measurement and EQ-CMR. ECVCT was compared to the reference ECVCMR and conventional amyloid measures: bone scintigraphy and clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area). ECVCT tracked clinical markers of cardiac amyloid severity (NT-pro-BNP, Troponin, LVEF, LV mass, LA and RA area), and bone scintigraphy amyloid burden (p
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.