Abstract
The lower cost of sensors is making possible the acquisition of big data sets in several applications and research areas. Indoor air quality and commuter exposure to pollutants are some of these areas, which can have impacts on our livelihood. The main objective of this exploratory research was to assemble portable equipment along with a prototype, one low-cost and easy to replicate in any location worldwide. We answer how CO2, noise and energy expenditure compare in different transportation modes with indoor environments (metro, bus and car). It was intended to be carried by a subject on all commutes. The low-cost equipment assembled has the ability to measure ambient CO2, noise levels, heart rate and geographic coordinates. The field campaign was conducted on an urban commuting route, in Lisbon city, between Rossio (downtown of Lisbon city) and Campo Grande (near FCUL campus). It took place during 3 weeks in school break and 3 weeks in the school period to grasp some differences between these periods of the year. The heart rate data was used to calculate the subject energy expenditure and the geographic coordinate data allowed for time and spatial analysis using a geospatial software package. Our measurements totaled 70 one-way trips and 358,140 data points. Temporal and spatial analysis yielded the following results: The metro presents the lowest median CO2 concentrations of 693 ppm and the bus the highest with 1085 ppm. The bus had an equivalent continuous sound average (Leq) of 75 dBA, while the metro had 85.2 dBA. Based on the metabolic equivalent of task (MET) calculations, the metro displays the least sedentary behavior, while the bus presents the most sedentary behavior with up to 96.5% of its commute spent in this classification. The metro was the fastest mode of transportation based on the consistency of its travel times compared to the bus, which despite also being consistent, was slower by 1.8 times. The car measurement values reside in the middle of the metro and bus results. Despite this, it is considered the worst mode of transportation, as it goes against the idea of a less congested and clean city. It also has a highly variable commuting time, which sometimes makes it slower than the metro, especially during the school period. According to our results, we concluded that the metro had efficient indoor ventilation while the bus did not. There were several instances of inefficient ventilation with concentrations exceeding 1000 ppm, particularly between Restauradores and Saldanha due to overcrowding. Referring to the health impacts of noise, the metro dBA levels are not sustained for enough time to have any measurable negative impact. Sensor performance was considered acceptable for the CO2 sensor. The dBA and heart rate (HR) sensors were considered acceptable to sometimes irregular in nature, which was expected and taken into consideration.
Highlights
The lower cost of sensors is making possible the acquisition of big data sets in several applications and research areas [1]
Based on the metabolic equivalent of task (MET) calculations, the metro displays the least sedentary behavior, while the bus presents the most sedentary behavior with up to 96.5% of its commute spent in this classification
The main objective of this exploratory research was to assemble portable equipment and a prototype, all of low-cost and easy to replicate in any location worldwide
Summary
The lower cost of sensors is making possible the acquisition of big data sets in several applications and research areas [1]. We considered activities that mostly happen outdoors, such as public and private transportation while commuting, to take place in indoor environments that can accumulate CO2 To aggravate this situation, mainly as a result of the metabolic process in humans, the simple use of indoor space by people produces and accumulates CO2 that further degrades the overall air quality. Seppänen literature review [2], which goes on saying that in about half of the CO2 papers it reviewed, there is evidence to suggest that concentrations below 800 parts per million (ppm) significantly decrease symptoms associated with SBS These studies are conducted in office environments; CO2 concentrations have been researched inside public transportation too. It is worth pointing out that they mention it is impossible to be sure these effects are solely due to the CO2 increase [5]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.