Abstract

The paper aimed to determine the validity of finite element analysis of tibia bone affected by Osteogenesis Imperfecta (OI) under various angle of bowing of the bone. Finite element (FE) model of human tibia bones were developed with various degree of bowing to simulate different severity of OI, and then the geometrical models of these FE models were used to develop bone specimen using fused deposition method (FDM) rapid prototyping technique. Compression tests were conducted to the bone specimen and FE analysis were performed by simulating conditions of the compression test, and then results from the compression test and FE simulation were compared. It have been found that both of the results corresponded to each other, therefore it is concluded that FE analysis is able to simulate the mechanical response of tibia bone with OI.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.