An experimental study was carried out to understand the phenomena of the boiling flow of liquid nitrogen in inclined tubes with closed bottom by using a high speed motion analyzer. The experimental tubes are 0.018 and 0.014 m inner diameter (ID) and 1.0 m in length. The range of the inclination angle is 45°–90° from the horizontal. The experimental observation on the liquid slug was carried out along the tubes. Statistical method was employed to analyze the experimental data. The experiment analyzed the influences of the inclination angle and the tube diameter on the liquid slug length and velocity. The results show the liquid slug propagation velocity increases with the decrease of inclination angle θ. For all cases, the maximum values of the mean liquid slug lengths were obtained at θ = 60°. The mean liquid slug lengths were greater for large tube at higher tube position. These conclusions provide a basis for further study liquid slug of cryogenic two-phase undeveloped slug flow.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.