Abstract

In this study, confined masonry specimens with regular arranged openings are tested in order to study the influence of different enhancements of the columns on seismic failure modes. In particular, five brick masonry walls and three half-scale two-storey masonry structures are tested under quasi-static loads. The experimental results show that increasing column ratio improves the seismic behavior of the wall specimens to some extent, but an excessive reinforcement ratio of the columns decreases the ductility. The global failure mode of the two-storey masonry structures is modified by inserting iron wires in the mortar bed joints, improving the structural collapse resistant capacity effectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.