One scale model of 1.5MW wind turbine frustum tower in Baiyun Obo was carried on pseudo-static test. The failure mechanism and characteristics, stress changes and distribution laws, hysteresis performance and ultimate bearing capacity were studied. Test results show that the wind turbine tower belong to the sudden extreme point instability failure; the buckling bearing capacity is as the ultimate bearing capacity of tower. The maximum stresses of tower mainly distribute at the variable wall thickness section and bottom, while other parts basically dont yield. This indicate that the material utilization of this kind of tower structure remains relatively low, structural design has yet to be improved, at the same time recommends that reasonable strengthen measures should be taken at the weakest part of tower. The P-Δ hysteretic curve of tower shows anti-"S" shape, the overall strength and stiffness degenerate more rapidly, which indicates that the plastic deformation and energy dissipation capacity of frustum tower is poor. The test conclusions could reflect the stress condition of prototype tower and provide references for design.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.