Abstract

An experimental study is presented in this work, where the distortion effect of a 4 kW photovoltaic domestic power plant, located in Hungary, has been examined. The power plant is connected to a low voltage grid by using a standard grid synchronized inverter. Based on the measured voltage and current signals we examined the frequency domain behavior of the power plant, and the effect of the power plant on the power quality, mainly the total harmonic distortion. The measurement database shows that the synchronous power injection of the photovoltaic domestic power plant has serious effect on the voltage distortion of the low voltage grid, and this effect highly depends on the actual generated power.Based on the experimental results, suggestions on how to operate the photovoltaic domestic power plant are formulated that enable its energy-efficient operation with minimal distortion effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.