Abstract
This study presents experimental results of heat transfer coefficient and pressure drop during two-phase flow of R134a in a horizontal tube containing twisted-tape inserts. The test section is a 2 m long copper tube of 15.9 mm inner diameter. The experiments were performed for tapes with twist ratios of 9 and 14 and a tube without insert. The mass velocity ranged from 75 to 200 kg m−2 s−1 and the vapor quality from 5 to 95%, for adiabatic condition and for constant heat flux of 10 kW m−2. Experimental pressure drop and heat transfer coefficient results are presented, and also an analysis of overall enhancement due to the inserts. The use of twisted-tape inserts is suitable if applied to the high vapor quality region of the evaporator and under high mass velocities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.