Abstract

A new set of experimental data on the particle collection characteristics of small cyclones is reported. The collection efficiency for particles ranging from 2 to 10 μm in diameter was measured systematically for nine cyclones at flow rates ranging from 8.8 to 18.4 L/min. Special emphasis was given to the effects of the exit tube size and of the cyclone body size on the particle collection efficiency. The size ratio of the exit tube to the cyclone body was varied from 0.24 to 0.80. The experimental results show that the stiffness of the particle collection cutoff with size does not change noticeably with a change in the cyclone body size while operation of a cyclone at a low flow rate can cause the particle collection characteristics to become less stiff. It was also found that the exit tube diameter influences the particle collection efficiency substantially, with results showing that as the exit tube size is decreased, the collection efficiency increases. A large cyclone body size increases the efficien...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.