Abstract

This paper presents the experimental results of an adsorption icemaker operating without refrigerant mass recovery and under two kinds of mass recovery cycles. The generation temperatures used in the experiments were 85 and 115 °C. At the lower generation temperature, the cycle with mass recovery in double stage produced the highest cycled mass, rate of ice production, cooling capacity and its COP was similar to that obtained in the cycle with conventional mass recovery. At generation temperature of 115 °C, the best performance was obtained with the cycle that employed conventional mass recovery. The cycle with mass recovery in double stage generated 42% more refrigerant mass than the cycle without mass recovery when the generation temperature was 85 °C, while at generation temperature of 115 °C, the cycle with conventional mass recovery generated 37% more mass than the latter. These results show that mass recovery can be an efficient process to enhance the performance of adsorption machines for ice making.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.