Abstract
The paper presents the results of experimental research of the heat transfer processes during the operation of a WWER steam generator in emergency condensation mode. The experiments are carried out at a research facility with a test section in the form of a single-tube model of a steam generator. The geometric characteristics of the tube and the main research parameters, such as temperature and pressure, are similar to the real steam generator. Several stages of research are planned: with pure water steam, with a fixed concentration of boiling boric acid and with a variable concentration of acid in the solution. The results of the first series of experiments performed on pure water steam are presented. As a result of research, the heat flux density is determined, and the values of the heat transfer coefficient during steam condensation in a single horizontal tube are calculated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.