Abstract

An experimental study has been conducted to examine free convection in a window with an enclosed aluminum venetian-type blind. The unique feature of this experiment was that the blind slats were heated electrically to simulate absorbed solar radiation. Convective heat transfer measurements and temperature field visualization were obtained using a Mach–Zehnder laser interferometer. Optical measurements were made for two glazing spacings, two blind slat angles, two blind heat flux levels, and two glazing temperature differences. Both local and average convective heat flux data were obtained in the center region of the tall air-filled enclosure. At the widest glazing spacing, the temperature field was found to be unsteady. For these cases, the temporal fluctuation of the local convective heat transfer was time-averaged using a high speed camera. The experimental results have been compared to a simplified method in the literature for predicting the center-glass heat flux for this configuration.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.