Abstract
This paper reports on cryogenic distillation experiments that have been performed with an H- D-T system (1.5 g of tritium) by using two columns with different inner diameters (1 and 2 cm) and different size packings (a 3-mm Dixon ring for the larger column and a 1.5- mm Dixon ring for the smaller column). The height equivalent to a theoretical plate (HETP) values measured during total reflux operation ranged from 4 to 6 cm for both columns and showed no apparent dependence on vapor velocities. The HETP values under total recycle operation, which varied from 3 to 6 cm, gradually decreased with increasing reflux ratios. The feed flow rates also had influenced the HETP. Consequently, the HETP values were correlated by the flow rates of the feed and vapor streams of the column and by the reflux ratio.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.