Abstract

The paper deals with the results obtained during experimental research of the heat transfer performances of cross-flow heat exchanger with highly viscous fuel oil flowing normal to the tube bundle with Re < 1 and Pr ∼ 2000. Experimental research was performed on the oil cooler that consist of 50 in-line, with 10 mm outside tube diameter, 100 mm tube length, with both longitudinal and transversal tube pitch of 19.5 mm. Comparison of experimental results with equations from literature sources showed that dispersion of measured and calculated values is significant. In order to obtain more accurate equation statistical analysis was performed and dimensionless equation in the form Nu D = 3.17 · Re D c 0.1 · Pr 1 / 3 · Pr Pr w 0.25 is obtained. Similar form of equation can be obtained when Reynolds–Colburn analogy is applied on previous experimental research of pressure drop.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.