Abstract

An experimental R134a automotive air conditioning (AAC) system with a variable capacity compressor has been developed and equipped with various mechanical instruments. The system has the capability of using both a thermostatic expansion valve (TXV) and an orifice tube (OT) as an expansion device. The system has been tested by varying the compressor speed and temperatures of the air streams entering the condenser (Tcond,ai) and evaporator (Tevap,ai). Using experimental data, the performance parameters of the AAC system for TXV and OT operations have been evaluated. The results show that the cooling capacity usually increases with the compressor speed. However, the exergy destruction in the system also increases and the coefficient of performance (COP) decreases with the compressor speed. The cooling capacity and COP decrease on rising Tcond,ai, while they increase on rising Tevap,ai. The TXV operation usually yields slightly higher cooling capacity and COP and lower exergy destruction compared with OT operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.