Abstract
DC and bipolar voltage stresses are used to isolate mechanical degradation of the movable electrode from charging mechanism in microelectromechanical capacitive switches. Switches with different metals as the movable electrode were investigated. In titanium switches, a shift in the pull-in voltages is observed after dc stressing whereas no shift occurs after the bipolar stressing, which is to be expected from charging theory. On switches with similar dielectric but made of aluminium, the narrowing effect occurs regardless if dc or bipolar stressing is used, which indicates the mechanical degradation as the mechanism responsible.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.