Abstract

The importance of the unsteady effects between casing treatment and rotor is still not clear. Experiments are conducted in a transonic compressor with arc skewed slot casing treatment configurations. The experimental results indicate that the unsteady excitation frequency due to slot number of casing treatment is one of the most important factors influencing compressor performance. And compressor performance can be overall enhanced through optimizing this unsteady excitation frequency. For the transonic compressor herein, peak efficiency, stall margin and the maximum flow mass can be improved by 0.17%, 19.86% and 0.81% respectively at near design rotating speed, which can reach up to 1.13%, 57.84% and 1.57% respectively at part design speed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.