Abstract

On the basis of a 12.5 kW multi-split variable refrigerant flow (VRF) system, the nominal cooling capacity ratio (θ) and the COP of the baseline system with fin-tube heat exchanger (FTHX) and the VRF system with microchannel heat exchanger (MCHX) were obtained for different part load ratios (PLRs). The key control strategies of the VRF system were presented. The charged amount of refrigerant ratio β and the pressure drop ΔP of the MCHXs were also achieved. The experimental results show that the β of the MCHXs was decreased by 26.67–46.67% and the optimum charged amount of refrigerant of a VRF system with an MCHX should obtain a discharge pressure between 3.0 MPa and 3.15 MPa for PLR round 100%. The VRF system with the MCHXs obtained large ΔTHX to avoid refrigerant flashing expansion in long pipe application and it could provide residents with better thermal comfort in hot seasons or regions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.