Abstract

The present work experimentally investigated the operating characteristics of a miniature loop heat pipe (LHP) under different power cycle. The miniature LHP with flat evaporator of 8mm thick is made of copper. The evaporator with sintered copper power wick is in series structure with compensation chamber. Water is working fluid. It is found that the LHP can start up at heat load of 15W with temperature oscillation and the maximum heat load is 160W with Rl=0.068°C/W. The LHP operates unstably under low heat load. The oscillating frequency of temperature rises with heat load increased. The operating performance of the LHP is affected by the power cycle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.