AbstractThis paper presents the results from experimental investigations focused on the thermal and structural behavior of composite beams with shear connections subjected to fire conditions. Five partial composite beams with flat, lightweight concrete slabs were designed according to current U.S. codes and standards. Vertical loading was applied to the composite beams, and the surfaces of the steel and concrete were heated using high-temperature ceramic radiant heaters. Variations in the loading and heating protocol provided insight into the mechanical response and failure modes of composite beams and connections. There was an overall reduction in the composite beam load-carrying capacity due to heating, both at elevated temperatures as well as postfire ambient conditions. Concrete compression failure occurred at moderate steel temperatures (350–500°C) combined with overloading. In cases where service level loading was applied, the composite beams and connections sustained the loading and heating up to s...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.