Abstract
This study summarizes the evaluation of rainwater quality and its potential for non-potable applications in the city of São Paulo, Brazil. An experimental system was installed at the Centro de Técnicas de Construção Civil (Civil Construction Techniques Centre, Escola Politécnica, University of São Paulo) such that analysis of the physical, chemical and bacteriological composition of rainwater—total and faecal coliforms, Clostridium Sulphite-reducer, Enterococcus and Pseudomonas aeruginosa—could be conducted. The need for water treatment was also evaluated in order to match quality to specific uses. Rainwater samples were collected from the roof by an automatic sample collector. Samples were also collected from a rainwater storage tank. In the operation of the system, analysis of rainwater's potential use in non-potable applications, such as flushing toilet bowls, was also conducted. The results obtained did not meet recognised quality standards, leading to the conclusion that water disinfection prior to use is required.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.