Abstract

A transonic compressor rotor blade cascade was tested in order to elucidate the flow behaviour in the transonic regime and to determine the performance characteristic in the whole operating range of a rotor blade section. The experiments have been conducted in a transonic cascade wind tunnel, which enables tests even at sonic inlet velocities. The influence of the upstream Mach number between 0.8 and 1.1 and the inlet flow angle between choking and stalling of the blade row was investigated. The effect of the axial velocity density ratio (AVDR) could be studied by applying an endwall suction device. Furthermore the level of the shock losses was determined from a wake analysis. A final comparison of cascade losses and those of the corresponding rotor blade element shows good agreement which underlines the applicability of the cascade model in the design of axial flow turbomachines.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.