Abstract

This paper concerns the assessment of the surface temperature of copper electrodes submitted to an electric arc in a non stationary regime in air. An infrared camera is used to measure the decrease of the temperature surface just after a controlled and very fast arc extinction. In the first part, the experimental method is described. In the second part, results are presented for 60–70 A with an electric arc duration in the range 3–4 ms. The temperature decrease after the arc extinction allows to reach an assessment of the surface temperature just at the arc switching off. In the present experimental conditions the mean temperatures reached for copper cathodes and anodes are in the range 750–850°C.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.